The quick answer

What should you do when your hot tub displays an error code?

An error code is a message from the spa’s control system. It may warn about restricted water flow, overheating, a temperature sensor, electrical equipment or a maintenance reminder. The meaning depends on the actual controller and production year—not just the hot tub brand stamped on the shell.

01 · Check the display

Write down the exact message

Take a photo showing the entire warning, the current water temperature and any other symbols. HL, FLO and Pr can have different meanings on different controllers.

02 · Identify your controls

Confirm the panel, not just the spa

Select your Bullfrog, MAAX or ŌWOW model below and compare the installed keypad or touchscreen to the manufacturer’s manual. A replacement control can change which codes apply.

03 · Stay safe

Don’t defeat a safety warning

If the water is too hot, there is an electrical concern, a pump appears stuck on, or the tub is running dry, stay out and seek qualified help. Never bypass switches or repeatedly reset a fault.

Stop-use warning: Do not enter water when overheating or dangerous hardware messages appear. Switch power off if your manufacturer’s instructions call for it, and contact a qualified professional. In freezing weather, lost heat or circulation also requires prompt attention.

Interactive tool • Step by step

Find your hot tub error code

Choose your brand and model, then identify the control panel actually installed on your spa. The finder will show matching manufacturer-documented or controller-family messages, possible causes and owner-safe checks. If your panel is unknown, the guide will not guess what an ambiguous code means.

Your hot tub, your control panel, your message

We never automatically assume that a spa model has the same control system in every year or configuration.

Step 1 • Brand


Choose a brand above to see the hot tubs in Custom LeisureScapes’ catalogue.

Type letters or words exactly as you see them. On some Balboa panels, an M-number is stored in the fault log while the screen shows a sentence.

Common codes for your selected panel
Choose a panel to view matching examples.

READY TO START

Which hot tub are you troubleshooting?

Choose Bullfrog, MAAX or ŌWOW above. If you don’t know your model or controller, use the symptom finder below for general, non-electrical first checks.

The interactive finder requires JavaScript. The complete explanation tables, checklists and FAQs below remain available without it.

For an exact diagnosis, refer to the owner’s manual and the identification label for the installed controller. This tool provides educational guidance, not a remote inspection.

Brand-specific troubleshooting

Why one error code can mean two different things

A hot tub’s model number is only one part of the identification. In Southwestern Ontario, owners may be dealing with a newly installed spa, an older model, or a spa whose controller has been replaced during a previous repair. The same two letters can mean entirely different things.

Example: HL

In Bullfrog’s current Gecko-based documentation, HL means the high-limit safety circuit has tripped. On some older Balboa-equipped spas, HL / HFL can instead flag a large temperature-sensor difference associated with poor heater flow.

Do not interpret HL without verifying the control system.

Example: Pr

In current Bullfrog A/M-Series message tables, Pr points to defective temperature probes or their detection circuit. On certain older Balboa panels, Pr indicates priming mode at startup—usually not a fault.

Identical letters do not guarantee an identical diagnosis.

Bullfrog X6L spa available at Custom LeisureScapes

Bullfrog Spas

Current X Series and A Series use different interface styles. Older Bullfrog generations can have different controls and message formats.

Explore Bullfrog models →

MAAX Spa 281 available at Custom LeisureScapes

MAAX Spas

MAAX and American Whirlpool controls vary by model year and installed spa pack. Verify the label before following Gecko or Balboa instructions.

Explore MAAX models →

ŌWOW 201-SE spa available at Custom LeisureScapes

ŌWOW Spas

Manufacturer listings identify a TP500 on some classic models and a TP700 on the 201-SE. Touchscreen models require version confirmation.

Explore ŌWOW models →

Reference library • Easy to scan

Common hot tub error codes explained

These tables help you recognize what an error may mean. They’re grouped by controller family, not just brand; some messages apply only to particular years, optional water-care systems or spa packs. The interactive finder above supplies more detailed first checks after you confirm the control.

Bullfrog A Series / M Series: documented Gecko-style messages

Message Meaning Suggested response
HL High-limit circuit has tripped. Stop use; assess overheating and seek professional guidance.
FLO, FLO-L01, FLO-L02 Water flow condition detected. Check level, filter condition and normal circulation safely.
NO FLO / CFLO No flow or a persistent no-flow condition. Heating may be stopped. Arrange service if normal flow is not restored.
OH, HR, Hr Overtemperature, relay hardware, or thermal safety warning. Do not enter; qualified service is appropriate.
Pr, AOH Temperature-probe fault or high internal equipment temperature. Professional diagnosis may be needed.
FLC, SP in, UPL Pressure-switch, supply-voltage or invalid software condition. Record the exact code; contact trained service personnel.

Source: Bullfrog’s 2026 A Series and M Series owner manuals. X Series and earlier production years may have different wording or codes. View Bullfrog owner manuals.

ŌWOW classic spas with Balboa BP-series controls

Code / displayed message Meaning What to do first
M016 • Water flow is low Flow through the heater may be insufficient. Confirm water level and normal circulation.
M017 • Water flow has failed Heater is disabled due to inadequate flow. Do not repeatedly reset; service if unresolved.
M028 / M027 Heater may be dry / heater is dry. Do not run a dry pump; follow refill/priming guidance.
M029 / M030 Spa water overheated / heater overheated. Do not enter water; follow the safety instructions.
M015 / M026 Temperature sensors disagree; persistent mismatch. Arrange service if the condition persists.
M031 / M032 Temperature sensor A / B fault. Contact a qualified technician.
M034 / M035 Possible stuck pump / hot fault. Power down as directed; do not enter.
M036 GFCI safety test failed. Contact qualified service; never bypass protection.

This code family requires a confirmed Balboa BP-series control pack. A TP500 or TP700 is the panel name; not every panel/pack combination has every message. ŌWOW manuals.

Older Balboa panels (where confirmed on a MAAX or ŌWOW)

Code What it indicates on compatible older controls Priority
HH / OHH, OH / OHS Heater or spa water too hot. Stop use.
SA, SB, SN Temperature sensor faults or disagreement. Service if persistent.
HL / HFL, LF Potential or persistent inadequate heater water flow. Check water/flow; service if repeated.
DR, DY Possible or confirmed dry-heater condition. Do not force continued operation.
IC, Pr, -- -- Freeze protection, priming mode or unknown temperature. Often informational, subject to context.

MAAX owner note: These tables are not a claim that all MAAX models use Balboa, Gecko or any one keypad. Check the exact pack and year, particularly on spas sold under MAAX or American Whirlpool names.

Before you book a repair

Six safe checks for a hot tub that is not heating or circulating normally

Flow-related faults often appear after a water change, when a filter becomes restricted, or when water level falls. These checks are deliberately limited to owner-visible items. Do not open a live electrical cabinet, loosen plumbing connections on energized equipment or bypass a protective device.

1

Check the fill level

Compare the water line with the fill indicator in your spa’s manual. A low level can let air enter the circulation system, especially while jets run.

2

Look for water movement

Observe jets, return flow or circulation indicators without opening the equipment. If a pump runs loudly but moves no water, stop following the manual’s instructions.

3

Inspect filter maintenance

A dirty or incorrectly seated cartridge may impede circulation. Follow the manufacturer procedure for shutting power off before handling filters, then clean or replace as directed.

4

Think about the last refill

An airlock may follow draining and refilling. Use only the owner-level priming procedure specified for your control; do not let a pump run dry.

5

Review heat mode and set temperature

Some systems use Ready/Rest, Standard/Economy or scheduled heating. A lower setting can mimic a heater fault. Do not override a genuine overheating or no-flow message.

6

Record what changed

Note the time, message, outside temperature, recent cleaning, power outage, refill or chemical adjustment. A clear service note can help the technician work efficiently.

No code? Still need answers?

Common hot tub problems that do not always show an error message

Hot tub is running but not heating

Start by comparing current and set temperature, then check the selected heating mode, water level and filter maintenance. A flow problem can prevent heating even while some jets work. A failed heater, sensor or electrical component needs service.

Jets feel weak or keep surging

Low water, closed jet controls, clogged filters, trapped air after refilling or a circulation problem may reduce performance. Don’t keep running a noisy pump without normal flow.

Breaker keeps tripping

Repeated tripping may point to an unsafe electrical condition or faulty equipment. Do not repeatedly reset the breaker or open the spa pack. Contact a licensed electrician or qualified spa technician.

Hot tub stopped after draining and refilling

A spa may need to prime its pumps, clear trapped air, recognize a proper water level and re-establish temperature sensing. Follow the exact startup procedure in the manual rather than copying steps from a different brand.

Pump makes humming or grinding noises

Possible causes include trapped air, flow restriction, a failing pump or a motor issue. If there is grinding, burning smell, unusual heat or no water movement, stop the affected equipment and request service.

Cloudy water or persistent foam

This is usually a water-care issue rather than a control-panel error. Start with a reliable water test, assess sanitizer and pH, clean filtration and review bather products. Never mix chemicals or guess at treatment amounts.

Related help: Visit Custom LeisureScapes’ hot tub drain and refill guide, browse spa chemicals and water-care supplies, or review professional hot tub services.

Especially important in Southwestern Ontario

When a hot tub stops heating during a London or Stratford winter

Frozen plumbing can turn a manageable heater or flow problem into a much larger repair. Cold weather does not change what an error code means, but it changes how quickly the problem deserves attention.

Check after an outage

Confirm the display has resumed normally, the spa is still heating and water is moving. Don’t assume automatic recovery without looking at the actual water temperature.

Protect circulation

If water flow stops or the temperature keeps falling, seek qualified advice promptly. Do not disable freeze protection, repeatedly cycle faulty equipment or leave an unattended spa without heat.

Do not simply drain it

Water can remain inside plumbing and pumps even after the shell is empty. Winterization requires the correct model-specific procedure, not just opening the drain.

For a season-long plan, read Is My Hot Tub Ready for Winter?. If you are shutting the spa down, see hot tub winterizing and closing rather than treating a standard drain as winterization.

Frequently asked questions

Hot tub error code FAQs for London & Stratford owners

What does FLO mean on a hot tub?

FLO usually points to a water-flow or circulation condition on compatible controllers, but the exact meaning and response depend on the installed spa pack. Check the correct fill level, visible circulation and filter maintenance according to your manual. If the heater is disabled or the warning persists, arrange service.

What does HL mean on Bullfrog, MAAX or ŌWOW?

It depends on the controller. In Bullfrog’s 2026 A/M-Series documentation, HL means the high-limit safety circuit has tripped. On some older Balboa controls found in other spas, HL/HFL refers to a sensor-temperature difference that may suggest inadequate flow. Never use an HL definition without confirming your panel.

What does Pr mean? Is it a hot tub error?

On applicable Bullfrog controls, Pr is listed as a temperature-probe or detection-circuit warning. On some older Balboa panels, Pr means priming mode after startup. The safest next step is to identify the controller and year before doing anything more.

Why is my hot tub not heating even though the jets work?

Check the actual temperature, heat mode, scheduled filtration and water level first. A dirty filter or insufficient heater flow can sometimes disable heating. Sensor faults, heater problems and electrical components require qualified diagnosis.

Do MAAX spas all use the same error codes?

No. MAAX and American Whirlpool spas have used different controls across models and production years. Confirm the installed keypad and equipment pack or the exact owner manual before using a Gecko- or Balboa-specific message table.

What do M016, M017 and M029 mean on ŌWOW?

On applicable Balboa BP-series controls, M016 indicates low heater flow, M017 indicates failed heater flow and M029 indicates excessive spa-water temperature. The actual screen may show words instead of the M-number, which can appear in a fault log. These definitions should not be applied to a portable VL260 panel.

Can I reset my hot tub error code myself?

Only when your model’s manual instructs you to, after the underlying cause has been corrected. Do not repeatedly clear overheating, dry-heater, pump, electrical or high-limit faults. Never bypass flow switches, GFCI protection or thermal safety devices.

What should I do if my spa stops heating during freezing weather?

Treat the loss of heat or circulation as time-sensitive. Record the exact message, check only owner-visible items, and contact a qualified spa service provider promptly. Do not simply drain the shell; freezing water may remain in the plumbing and equipment.

Does Custom LeisureScapes help with hot tub troubleshooting in Southwestern Ontario?

Custom LeisureScapes offers hot tub diagnostics and service for London, Stratford and surrounding Southwestern Ontario communities. You can describe the brand, model, symptoms and error message through its hot tub service request page.

Local service, real answers

Still seeing an error? Let Custom LeisureScapes help.

Based in London and Stratford, Custom LeisureScapes helps spa owners across Southwestern Ontario with hot tub troubleshooting, diagnostics, maintenance and seasonal care. Save the error code and a clear photo of your display before you request service.

London: 775 Wharncliffe Rd S • Stratford: 404 Erie St • Serving Middlesex, Perth, Elgin and Oxford Counties and surrounding communities.

Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.